EN
EN • 21
SITUATION
230/110V charger for the Service and
Starter battery.
PROBLEM
The 230/110V charger should charge
both the Service and the Starter bat-
tery, and be synchronized with all other
energy sources.
SOLUTION
The single output 230/110V charger is
connected directly to the Service battery.
The Starter battery is pulse charged
through SMARTPASS.
The solar panel will also maintaince
charge the Starter battery through
SMARTPASS.
TIP 6
See Tip 1, Tip 2, Tip 4 and Tip 5
The battery cables of the 230/110V
charger are connected directly to the
Service battery.
INSTALLATION SHEET 6
CONNECTING AC/DC CHARGERS
WARNING!
•Max23Vinput
•Donotconnecttwosolarpanelsinseries
WARNING!
D250S DUAL and SMARTPASS is not
reverse polarity protected
12V
RECOND
RECOND
NIGHT
NORMAL
MODE
D250S DUAL
12V
+OUT
+IN
+IN
+IN +OUT
+OUT
SMARTPASS12V